Skip to content
StrikeCyberStrikeCyber
Threat Radar · Actively exploited

Rockwell Multiple Products (CVE-2021-22681)

Exploited in the wild Added 5 March 2026 EPSS 63.6%OT

Quick answer

Yes. CVE-2021-22681 in Rockwell Multiple Products is being exploited by attackers: CISA added it to its Known Exploited Vulnerabilities catalogue on 5 March 2026. If you run affected Rockwell products, apply the vendor's fix now and check for signs of compromise.

ConfirmedExploited in the wild
Not knownRansomware use
63.6%EPSS · top 1%
5 MarchAdded to CISA KEV

What is CVE-2021-22681?

Rockwell Multiple Products Insufficient Protected Credentials Vulnerability. Multiple Rockwell products contain an insufficient protected credentials vulnerability. Studio 5000 Logix Designer software may allow a key to be discovered. This key is used to verify Logix controllers are communicating with Rockwell Automation design software. If successfully exploited, this vulnerability could allow an unauthorized application to connect with Logix controllers. To leverage this vulnerability, an unauthorized user would require network access to the controller.

Description from the CISA Known Exploited Vulnerabilities catalogue.

Why it matters

Operational technology controls physical processes. Exploited flaws can disrupt production, safety systems or critical services, and many OT environments cannot be patched quickly.

Likelihood of exploitation activity in the next 30 days (EPSS)63.6%

Higher than 99% of all scored vulnerabilities.

Am I affected? How to check

  1. 1Confirm whether the affected product exists in your OT environment.
  2. 2Check network exposure, particularly any path from IT networks or the internet.
  3. 3Review vendor guidance on compensating controls where patching requires downtime.

What to do now

  1. 1Apply vendor mitigations and plan patching in the next maintenance window.
  2. 2Restrict and monitor all access paths into OT networks.
  3. 3Engage the vendor for incident support if exploitation is suspected.

CISA required action: Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.

How fast to patch

Under the Essential Eight, patches for internet-facing services should be applied within 48 hours when a working exploit exists, and higher maturity levels apply the same 48-hour target to applications such as browsers and office software. A vulnerability in this catalogue has, by definition, been exploited in the wild, so treat it as the 48-hour case.

Common questions

Is CVE-2021-22681 being exploited?

Yes. It is listed in CISA's Known Exploited Vulnerabilities catalogue, which only includes vulnerabilities with confirmed exploitation in the wild. It was added on 5 March 2026.

How do I fix CVE-2021-22681?

Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable. Check the vendor advisory for fixed versions, and if the system was exposed while unpatched, investigate it for signs of compromise.

Which Rockwell products are affected?

Check your installed version against the vendor advisory linked on this page. If the affected component is reachable from the internet and unpatched, assume it is at risk and act immediately.

Sources

1300 654 898